OILES FAQsSitemapContact UsHomeJAPANESECOMPANY INFORMATION
For BridgeFor BuildingProjectsFacilitiesSeismic Isolation and Vibration Control For Bridges and Buildings
FOR BUILDINGSeismic Isolation and Vibration Control For Bridges and Buildings
FPS (Friction Pendulum System)
Sliding pendulum isolation system

Flexible isolation system suitable for small to large scale buildings
AdvantagesStructureBasic FeaturesTest


Advantages

It is possible to set the oscillation period of a building regardless of its weight. High performance seismic isolation can be achieved for light buildings for which conventional methods have been considered impractical.
This system can reduce costs not only because of the low cost of the device, but also due to low installation cost.
Simple device works well, is easy to install, saves space and is practical for aseismic reinforcement (retrofit).
High durability and little chang in characteristics provide stable performance.
Maintenance is easy and requires only a simple visual check.
image

Structure

FPS is an isolation system consisting of upper and lower spherical plates and sliding puck; the spherical plates have sliding surfaces coated with OILES coating material, and the puck uses OILES skid to reduce friction.

Structures

Simple pendulumMotion of a pendulum

The period of a simple pendulum depends on the length of the string, not on its weight.
The period of FPS using the pendulum principle can be adjusted by changing the radius of the sliding surfaces. FPS also provides a restoring force due to gravity.
In addition, sliding surfaces on the plates provide for significant displacement in a compact device.

Friction pendulumMovement of OILES sliding material

OILES sliding material can absorb and dampen vibration energy as well as alleviating the shock of an earthquake.

Page Top
Basic features

This chart shows the relationship between force and displacement when FPS is subjected to extreme deformation as would be expected in a major earthquake.
Design values concur closely with physical measurements of performance, demonstrating high accuracy of the design method.
Characteristic restoring force of FPS are shown by two lines (bi-linear model). This characteristic makes structural modelling relatively simple.


Basic features

Test

Test of contamination by foreign matter

Results of testing of the effects of contamination of the FPS on its characteristics (friction factor) showed that performance as an isolation system does not change significantly.

Test of contamination by foreign matter

Cyclic durability Test

Results of a cyclic displacement test applied to an FPS at a speed equivalent to an actual seismic event shows that its characteristics (friction factor) remained stable, indicating good durability.

Cyclic durability test

Page Top

Seismic Isolation
LRB
LRB-S
RB / RB-S
SSR
FPS
Vibration Control
Seismic Isolation of service equipment and valuable objects

Actual Data
Record of seismic response observed in buildings with seismic isolation during the Great Hanshin Earthquake